Incubator for sale email

2.manual 2 of Incubator controller

Incubationtimeandparametertableofpheasantegg Daysofincubation 1-7days 8-14days 15-21days 22daysandafter Temperatureparameter 38.2℃ 38.0℃ 37.8℃ 37.6℃ Humidityparameter 60%RH 55%RH 60%RH 75%RH Fanparameter 2(15) 2(20) 1.5(25)

Incubation time and parameter table   of  pheasant  egg
Days of incubation 1-7days  8-14days  15-21days  22days and after 
Temperature parameter 38.2℃ 38.0℃ 37.8℃ 37.6℃
Humidity parameter 60%RH 55%RH 60%RH 75%RH
Fan parameter 2(15) 2(20) 1.5(25) 1.0(30)
Egg turning parameter 1.5(180) 1.5(180) 1.5(180) No turning 
 
Under CUSTOM MODEL ,parameter not change over time 
Remark:1.after one incubation period finished (chicken ,duck ,goose ,pigeon and pheasant )
,the system not reset automatic,user can choose the model again ,
or in the mean time press the RDUCCE  and MODEL button (3 seconds or more )
will reset the days of incubation and enter second incubation . 
 
Ⅴ、CUSTOM SETTINGS :
1.Temperature and humidity settings 
Under the “CUSTOM”model (the light of “custom”on ),user can set the temperature and humidity 
.like incubation need  the temperature is 38℃,humidity is 60℃,
then press  “settings” button and rasing the hands, “setting temperature window SV”display PP , 
“setting temperature window SV”blinking display 
current temperature setting data ,through pressing “up”and “down”buttons to adjust ,
and adjust to 38.0℃.Pressing the SETTINGS  
button and rasing the hands , “setting humidity window SV”display HH ,
 “setting humidity window SV” blinking display current humidity setting data ,through pressing “up”
and “down”buttons to adjust ,and adjust to 60℃.
After finished setting ,press to “settings “ to exit or no pressing for more than 10 seconds ,
systems can exit automatic ,and the modification parameter before saved automatically .
 
2.Interval adjust under the CUSTOM model (user not need  set ,and has finished setting completely before leave factory )
Under the normal working conditions ,holding the “setting” and “up”button (3 seconds and more ) , 
“setting humidity window SV”display P1 ,
 “setting humidity window SV”blinking to display P1 current data ,if need to change ,press “up”
 or “down”to adjust .if need to change next parameter ,pressing “setting” to adjust parameter .
No. Parameter name Parameter ID Seeting range Default value
1 Tempreature for alarm if over P1 0-99.9℃ 38.6
2 Tempreature for starting fan if over P2 0-99.9℃ 37.9
3 Tempreature for stopping main heater P3 0-99.9℃ 37.8
4 Tempreature for starting main heater P4 0-99.9℃ 37.6
5 Tempreature for starting backup heater P5 0-99.9℃ 37.5
6 Tempreature for alarm if lower P6 0-99.9℃ 37.0
7 Humidity for alarm if over H1 0-99% 80%
8 Humidity for stopping wet H2 0-99% 65%
9 Humidity for starting wet H3 0-99% 60%
10 Humidity for alarm if lower H4 0-99% 40%
 

Copyright  2015 Xinchang Global Co.Ltd www.xch86.com www.incubatorforegg.com